Founded in 1993
  Year: 2004 | Volume: 12 | Issue: 3 | Pages: 152-158
  Onconet
  PREDICTIVE ECG CODING USING LINEAR TIME-INVARIANT MODELS
Boskovic A, Despotovic M, Bajic D.
  DOI:
  Abstract:
  Electrocardiogram (ECG) signal compression suffers of lack of standards for analogue-digital conversion. Results of this study have shown that 8 bits/sample, although frequently in use, does not satisfy quality criteria for medical doctors. This paper also presents predictive technique for lossless ECG compression using linear time-invariant models. Tests on clinically measured ECG signals confirm a very good performance in terms of compression ratio.
  Key words: Electrocardiography; Signal Processing, Computer Assisted; Analog-Digital Conversion; Linear Models